keywords:
Bookmark and Share



Front Back
GEN FAIL
GEN FAIL
1. Gen Field & Gen Reset Circuit Brakers  Check In
2. Gen Switch  Reset then On
*If Power is not restored then
3. Gen Switch Off - Land As Soon As Practical
Excessive Electrical Load
1. Generator Switch, OFF
2. Battery Switch, OFF
Land As Soon As Practical
BAT TEMP
B III
1. Battery Switch OFF
*if temp light goes out
2. Battery Switch ON

L Series N/A
BATT HOT
Battery Switch OFF
B III/L-1 Land As Soon As Possible
L-3/4 Land As Soon As Practical
if BAT RYL light Land As Soon As Possible
BAT RYL
L Series
If BAT HOT light
Land As Soon As Possible
TRANS OIL TEMP
or
TRANS OIL PRESS
1. Reduce Power
2. Verify Fauld w/ Gauge
Land As Soon As Possible
Engine Oil Pressure Low, High, or Fluctuating
Oil Pressure below min or above max
Land As Soon As Possible

Oil Pressure Fluctuation, Monitor Pressure
Land As Soon As Practical
Engine Oil Temp High
Land As Soon As Possible
LOW FUEL
Land As Soon As Practical

B III- 17-20 Gal Fuel Remaining (38min)
L    - 50-75# Fuel Remaining (12min) L1 80# (20 min)
AF FUEL FILTER
Land As Soon As Practical
-B-III, L3/4
Land As Soon As Possible -L1
R/L FUEL BOOST PUMP
Decend below 6000 PA

B III (only 1)
Land As Soon As Practical
*Plan 10 gal unusable fuel

L Series
R or L Light
Land As Soon As Practical
Both R and L Light
Land As Soon As Possible
*
Plan 150# unusable fuel
*85# if fuel qty switch
Hydraulic System Failure
1. Adjust Airspeed 61 to 69 kts
2. Hydraulic circuit breaker OUT
* if Hydraulic IS NOT Restored
3. Hydraulic sys circuit breaker IN
4. Hydraulic sys switch OFF
Land As Soon As Practical
Engine Compressor Stall
1. Collective, Reduce Power
2. TOT/N1, Check Normal
3. Engine Anti Ice, ON
4. Collective, Adjust As Required
5. TOT/N1, Monitor
CHIP LIGHT
Any Chip Light
Land As Soon As Possible
x of y cards