keywords:
Bookmark and Share



Front Back
Slope of ramp of road-way to sidewalk.
1/3 - 1/4
Slope of driveway to sidewalk where the height of curb is 200 mm and above.
One is to Eight (1:8)
Minimum vertical clearance of primary lines from the crown of the pavement when crossing the highway.
10.00 mts.
Minimum vertical clearance of primary lines from top of sidewalk when installed along the side of the highway.
7.5 mts.
Vertical clearance of secondary lines from sidewalks along or crossing the street.
7.5 mts.
Minimum clearance of conductors from the highest point of a roof.
2.50 mts.
Maximum height of a dumbwaiter.
1.20 mts.
Maximum area of a dumbwaiter.
3,861 sqcms.
Minimum clearance of conductors from any platform or ground or projection from which they might be reached.
3.00 mts.
Minimum vertical clearance of service drop of communication lines above ground at its point of attachment to than building or pedestal.
3.00 mts.
Vertical clearance of a service drop communication line when crossing a street.
5.50 mts.
Maximum capacity of a dumbwaiter.
277 kgs.
Minimum width of an access road to a cul-de-sac.
3.00 mts.
Unit area per occupant for dwellings.
28.00 sqm.
Unit area per occupant for Hotels.
18.6 sqm.
Unit area per occupant for offices and garages.
9.30 sqm.
Unit area per occupant for class rooms.
1.80 sqm.
Unit area per occupant for stores - retail sales rooms upper floors.
5.60 sqm.
Unit area per occupant for nurseries for children.
3.25 sqm.
Unit area for stores -retail sales room for basement and ground floor.
2.80 sqm.
Unit area for hospitals and sanitaria.
8.40 sqm.
Unit area per occupant for aircraft hangars without repairs.
46.50 sqm.
Unit area per occupant for warehouses and mechanical equipment room.
28.00 sqm.
Unit area per occupant for theaters and the like.
0.65 sqm.
Parking requirement for Hotels.
1 slot/5 rooms
Parking requirement for public assembly buildings such as cinemas, auditoria, theaters, and the like.
1 slot/50 sqm. Of spectators' area
Parking requirement for multi family living unit of 50 sqm floor area.
1slot/8 units
Parking requirement for multi family living unit above 100 sqm floor area.
1 slot/unit
Parking requirement for multi family living unit for 50-100 sqm floor area.
1 slot/4 units
Parking requirement for clubhouses, beach houses, and the like.
1 slot/100 sqm of gross flr.area
Parking requirement for motels.
1 slot/unit
Minimum parking requirement for the handicapped.
1 slot/50 parking slots
Parking requirement for colleges and universities.
1 slot/5 classrooms
Parking requirement for elementary, secondary, and vocational schools.
1 slot/10 classrooms
In BP344, the required width of a corridor.
1.20 mts.
Maximum slope of a drop curb towards the street.
1:20
Maximum slope of a drop curb towards adjoining curb.
1:12
Maximum spacing for wheelchair turnabouts.
12.00 mts.
Maximum slope of a ramp.
1:12
Maximum distance of handicapped parking from the structure served.
60.00 mts.
Preferred width of corridor for the disabled.
1.50 mts.
Maximum height of a water closet from the floor.
0.50 mts.
Preferred height of switches from the floor.
1.10 mts.
Minimum height of a switch from the floor.
0.90 mts.
Maximum height of a switch from the floor.
1.20 mts.
Least dimension for a parking slot for the disabled.
3.70 mts.
In BP344, the minimum height of a handrail.
0.70 mtr.
Maximum length of a ramp for wheelchair.
6.00 mts.
Minimum length of a ramp landing for wheelchairs.
1.50 mts.
One or more habitable rooms which are occupied or which are intended or designated to be occupied by one family with facilities for cooking , sleeping, living, and eating.
Dwelling unit